Categories
Base Metals Energy Junior Mining Project Generators

F3 – Extends Mineralization with 67.0m of Radioactivity at Tetra Zone

Largest Radioactive Intervals to Date on Project

Kelowna, British Columbia–(Newsfile Corp. – August 5, 2025) – F3 Uranium Corp (TSXV: FUU) (OTCQB: FUUFF) (“F3” or “the Company“) is pleased to announce hand-held scintillometer results at Tetra Zone, where the widest intervals of radioactivity to date on the Patterson Lake North Project have been intersected with PLN25-217, which intersected a total of 67.0m composite radioactivity between 299.5m and 414.5m, including 49.0m of continuous radioactivity between 347.5m and 396.5m. Additionally, PLN25-212, approximately 23m up-dip of PLN25-217 and 31m along strike from the discovery hole PLN25-205, intersected the second widest interval to date with 39.5m composite radioactivity between 330.0m and 409.5m, including 27.5m of continuous radioactivity between 360.5m and 396.5m.

2025 Handheld Spectrometer Highlights:

Tetra Zone

PLN25-217 (line 11280S):

  • 0.5m interval with radioactivity between 299.5m and 300.0m, and
  • 0.5m interval with radioactivity between 315.5m and 316.0m, and
  • 7.5m interval with radioactivity between 336.5m and 344.0m, and
  • 49.0m interval with radioactivity between 347.5m and 396.5m, and
  • 9.0m interval with radioactivity between 399.5m and 408.5m, and
  • 0.5m interval with radioactivity between 414.0m and 414.5m.

PLN25-212 (line 11310S):

  • 2.5m interval with radioactivity between 330.0m and 332.5m, and
  • 0.5m interval with radioactivity between 346.5m and 347.0m, and
  • 0.5m interval with radioactivity between 354.0m and 354.5m, and
  • 27.5m interval with radioactivity between 360.5m and 388.0m, and
  • 6.0m interval with radioactivity between 394.0m and 400.0m, and
  • 2.5m interval with radioactivity between 407.0m and 409.5m.

Sam Hartmann, Vice President Exploration, commented:

“The substantial radioactive widths intersected in these drill holes were truly unexpected and highlight the significant potential we see at the Tetra Zone. Despite challenging drilling conditions and the non-traditional style of mineralization, each hole provides valuable insights into deposit model generation and drill plan adaptations. Notably, PLN25-217 confirms a theorized strike direction deviating from the current conductor model, and we will continue to explore this trend. To improve our conductor modeling around the Tetra Zone area, we are planning a ground geophysical program based on a tighter grid to support larger step-outs along the Tetra Zone, which stands to reduce the number of drill holes required for targeting. Additionally, we cored two drill holes at the JR Zone using casings set last winter with PLN25-215 and -216, which tested for crosscutting structures; those assays will be included in our maiden resource estimate, expected in Q4. We are very excited and look forward to further uncovering this unique system hosting the Tetra Zone.”

Map 1. Broach Lake – Tetra Zone Scintillometer Results

To view an enhanced version of this graphic, please visit:
https://images.newsfilecorp.com/files/8110/261242_985f0bcef4782a44_002full.jpg

Map 2. Patterson Lake North – JR Zone Scintillometer Results

To view an enhanced version of this graphic, please visit:
https://images.newsfilecorp.com/files/8110/261242_985f0bcef4782a44_003full.jpg

Table 1: Drill Hole Summary and Handheld Spectrometer Results

Collar Information* Hand-held Spectrometer Results
 On Mineralized Drillcore 
(>300 cps / >0.5m minimum)
Athabasca Unconformity Depth 
(m)
Total 
Drillhole
Depth
(m)
Hole IDSection LineEastingNorthingElevationAzDipFrom
(m)
To
(m)
Interval
(m)
Max
CPS
PLN25-21111340S589409639796258446-75160.50161.000.50320160.9548
PLN25-21211310S589368639797058440-72330.00330.500.50360164.2458
330.50331.000.50440
331.00332.001.00<300
332.00332.500.50310
346.50347.000.50330
354.00354.500.50380
360.50361.000.50410
361.00362.001.00<300
362.00362.500.50310
362.50363.000.50510
363.00363.500.50470
363.50364.000.50510
364.00364.500.50820
364.50365.000.50420
365.00365.500.50310
365.50366.000.50410
366.00366.500.50510
366.50367.000.50910
367.00367.500.501100
367.50368.000.501500
368.00368.500.50900
368.50369.000.50990
369.00369.500.502500
369.50370.000.503100
370.00370.500.501400
370.50371.000.50560
371.00371.500.501000
371.50372.000.50480
372.00372.500.50470
372.50373.000.50420
373.00373.500.501100
373.50374.000.50680
374.00374.500.503100
374.50375.000.501700
375.00375.500.50930
375.50376.000.50370
376.00376.500.50330
376.50377.000.50320
377.00377.500.50390
377.50378.000.50460
378.00378.500.502000
378.50379.000.503000
379.00379.500.503300
379.50380.000.502500
380.00380.500.50700
380.50381.000.50960
381.00381.500.503100
381.50382.000.50390
382.00382.500.50700
382.50384.001.50<300
384.00384.500.50310
384.50385.000.50670
385.00385.500.50320
385.50386.000.50670
386.00387.501.50<300
387.50388.000.50560
394.00394.500.50400
394.50395.000.50430
395.00395.500.50660
395.50396.000.50680
396.00396.500.50340
396.50397.000.50<300
397.00397.500.50380
397.50398.000.50340
398.00398.500.502000
398.50399.000.503000
399.00399.500.501000
399.50400.000.50520
407.00407.500.50360
407.50408.000.50320
408.00408.500.50<300
408.50409.000.50360
409.00409.500.50350
PLN25-21311325S589359639795958445-73Pilot hole for wedged hole below154.3224
PLN25-213W111325S589359639795958445-73278.00278.500.50750154.3434
278.50279.000.50430
279.00279.500.50550
326.00326.500.50530
326.50328.502.00<300
328.50329.000.50300
346.00346.500.50380
389.50390.000.50530
392.50393.000.50300
PLN25-21411340S589404639797858446-75342.00342.500.50860155.7507
342.50343.000.50430
382.50383.000.50360
PLN25-215090S5878496410603546348-59249.00249.500.50370194.4281
249.50250.000.50710
250.00250.500.50330
252.50253.000.50350
257.50258.000.50320
PLN25-216075S587778641071254655-64169.50170.000.50310194.3239
211.50212.000.502900
213.00213.500.50370
PLN25-21711280S589393639802658534-85299.50300.000.50300160.1575
315.50316.000.50460
336.50337.000.50310
337.00338.001.00<300
338.00338.500.50480
338.50340.001.50<300
340.00340.500.50450
340.50341.000.50650
341.00341.500.50320
341.50343.001.50<300
343.00343.500.50330
343.50344.000.50330
347.50348.000.50570
348.00348.500.50580
348.50349.000.50<300
349.00349.500.50340
349.50350.000.50<300
350.00350.500.50340
350.50351.000.50470
351.00351.500.50320
351.50352.000.50<300
352.00352.500.50700
352.50354.502.00<300
354.50355.000.50400
355.00355.500.505100
355.50356.000.50730
356.00356.500.50910
356.50357.000.50<300
357.00357.500.501000
357.50358.000.50910
358.00358.500.501100
358.50359.000.50490
359.00359.500.50360
359.50360.000.50630
360.00360.500.50680
360.50361.000.50350
361.00361.500.50540
361.50362.000.501200
362.00362.500.50430
362.50363.000.50680
363.00363.500.50540
363.50364.000.50330
364.00364.500.50810
364.50365.000.50610
365.00365.500.501000
365.50366.000.501100
366.00367.001.00<300
367.00367.500.50510
367.50368.000.50420
368.00368.500.50<300
368.50369.000.50340
369.00369.500.50820
369.50370.000.501900
370.00370.500.503300
370.50371.000.502200
371.00371.500.503500
371.50372.000.508500
372.00372.500.504500
372.50373.000.501100
373.00373.500.50630
373.50374.000.501200
374.00374.500.501300
374.50375.000.501300
375.00375.500.50800
375.50376.000.50310
376.00376.500.50300
376.50377.000.50620
377.00377.500.50760
377.50378.000.501700
378.00378.500.502100
378.50379.000.502600
379.00379.500.502700
379.50380.000.501400
380.00380.500.50720
380.50381.501.00<300
381.50382.000.502600
382.00382.500.50520
382.50383.000.501500
383.00383.500.50360
383.50384.000.50680
384.00384.500.50450
384.50385.000.50<300
385.00385.500.50300
385.50386.000.50520
386.00387.001.00<300
387.00387.500.50350
387.50388.000.50370
388.00388.500.50440
388.50389.000.50480
389.00389.500.502100
389.50390.000.506400
390.00390.500.504400
390.50391.000.504500
391.00391.500.502400
391.50392.000.503200
392.00392.500.50750
392.50393.000.50<300
393.00393.500.50420
393.50394.000.50400
394.00394.500.50550
394.50395.000.50350
395.00395.500.50680
395.50396.000.50700
396.00396.500.50360
399.50400.000.50360
400.00400.500.503600
400.50401.000.505800
401.00401.500.502000
401.50402.000.50500
402.00402.500.50<300
402.50403.000.50420
403.00403.500.50530
403.50404.000.50320
404.00405.001.00<300
405.00405.500.50300
405.50406.000.50<300
406.00406.500.50370
406.50407.000.50400
407.00407.500.50310
407.50408.000.50<300
408.00408.500.50300
414.00414.500.50420

Handheld spectrometer composite parameters:
1: Minimum Thickness of 0.5m
2: CPS Cut-Off of 300 counts per second
3: Maximum Internal Dilution of 2.0m

The natural gamma radiation detected in the drill core, as detailed in this news release, was measured in counts per second (cps) using a handheld Radiation Solutions RS-125 spectrometer which has been calibrated by Radiation Solutions Inc. The Company designates readings exceeding 300 cps on the handheld spectrometer (occasionally referred to as a scintillometer in industry parlance; this colloquial usage stems from historical naming conventions and the shared functionality of detecting gamma radiation between a spectrometer and a scintillometer)-as “anomalous”, readings above 10,000 cps as “highly radioactive”, and readings surpassing 65,535 cps as “off-scale”. However, readers are cautioned that spectrometer or scintillometer measurements often do not directly or consistently correlate with the uranium grades of the rock samples and should be regarded solely as a preliminary indicator of the presence of radioactive materials.

Samples from the drill core are split into half sections on site. Where possible, samples are standardized at 0.5m down-hole intervals. One-half of the split sample is sent to SRC Geoanalytical Laboratories (an SCC ISO/IEC 17025: 2005 Accredited Facility) in Saskatoon, SK while the other half remains on site for reference. Analysis includes a 63 element suite including boron by ICP-OES, uranium by ICP-MS and gold analysis by ICP-OES and/or AAS.

All depth measurements reported are down-hole and true thicknesses are yet to be determined.

About the Patterson Lake North Project:

The Company’s 42,961-hectare 100% owned Patterson Lake North Project (PLN) is located just within the south-western edge of the Athabasca Basin in proximity to Paladin’s Triple R and NexGen Energy’s Arrow high-grade uranium deposits, an area poised to become the next major area of development for new uranium operations in northern Saskatchewan. The PLN Project consists of the 4,074-hectare Patterson Lake North Property hosting the JR Zone Uranium discovery approximately 23km northwest of Paladin’s Triple R deposit, the 19,864-hectare Minto Property, and the 19,022-hectare Broach Property hosting the Tetra Zone, F3’s newest discovery 13km south of the JR Zone. All three properties comprising the PLN Project are accessed by Provincial Highway 955.

Qualified Person:

The technical information in this news release has been prepared in accordance with the Canadian regulatory requirements set out in National Instrument 43-101 and approved on behalf of the company by Raymond Ashley, P.Geo., President & COO of F3 Uranium Corp, a Qualified Person. Mr. Ashley has reviewed and approved the data disclosed.

About F3 Uranium Corp.:

F3 is a uranium exploration company, focusing on the high-grade JR Zone and new Tetra Zone discovery 13km to the south in the PW area on its Patterson Lake North (PLN) Project in the Western Athabasca Basin. F3 currently has 3 properties in the Athabasca Basin: Patterson Lake North, Minto, and Broach. The western side of the Athabasca Basin, Saskatchewan, is home to some of the world’s largest high grade uranium deposits including Paladin’s Triple R project and NexGen’s Arrow project.

Forward Looking Statements

This news release contains certain forward-looking statements within the meaning of applicable securities laws. All statements that are not historical facts, including without limitation, statements regarding future estimates, plans, programs, forecasts, projections, objectives, assumptions, expectations or beliefs of future performance, including statements regarding the suitability of the Properties for mining exploration, future payments, issuance of shares and work commitment funds, entry into of a definitive option agreement respecting the Properties, are “forward-looking statements.” These forward-looking statements reflect the expectations or beliefs of management of the Company based on information currently available to it. Forward-looking statements are subject to a number of risks and uncertainties, including those detailed from time to time in filings made by the Company with securities regulatory authorities, which may cause actual outcomes to differ materially from those discussed in the forward-looking statements. These factors should be considered carefully and readers are cautioned not to place undue reliance on such forward-looking statements. The forward-looking statements and information contained in this news release are made as of the date hereof and the Company undertakes no obligation to update publicly or revise any forward-looking statements or information, whether as a result of new information, future events or otherwise, unless so required by applicable securities laws.

The TSX Venture Exchange and the Canadian Securities Exchange have not reviewed, approved or disapproved the contents of this press release, and do not accept responsibility for the adequacy or accuracy of this release.

F3 Uranium Corp.
750-1620 Dickson Avenue
Kelowna, BC V1Y9Y2
Contact Information
Investor Relations
Telephone: 778 484 8030
Email: ir@f3uranium.com

ON BEHALF OF THE BOARD
“Dev Randhawa”
Dev Randhawa, CEO

To view the source version of this press release, please visit https://www.newsfilecorp.com/release/261242